ON-BOARD DIAGNOSTIC [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)]


id0702k2126600


Outline

•  The on-board diagnostic system has on-board diagnostic, PID/data monitor, and A/C operation check functions.
•  The on-board diagnostic function has the following functions:
―  Malfunction detection function
•  Detects errors in input and output signals
―  Memory function
•  Stores detected malfunctions
―  Malfunction indication function
•  Displays detected malfunctions
•  The malfunction indication function, PID/data monitor, and A/C operation check functions can be performed by connecting the Mazda Modular Diagnostic System (M-MDS) to the DLC-2.

Block Diagram

am6xun00001433

Function


Malfunction detection function

•  The malfunction detection function detects errors in the input and output signals. (Ignition is switched ON (engine off or on))
•  If a malfunction is detected, a DTC is output to the DLC-2 through the malfunction indication function.
•  At the same time, malfunction detection results are sent to the fail-safe and memory functions.


Memory function

•  The memory function stores malfunctioning signal systems which are detected to be malfunctioning by the malfunction detection function.
•  The stored malfunction information is not cleared even when the ignition is switched off (LOCK) or the malfunction is repaired.
•  The stored malfunction information can be cleared by connecting the Mazda Modular Diagnostic System (M-MDS) to the DLC-2 and operating it.


Malfunction indication function

•  The malfunction indication function outputs present or past malfunctions to the DLC-2 as DTCs.
•  The DTCs can be read by connecting the Mazda Modular Diagnostic System (M-MDS) to the DLC-2 and operating it.
Malfunction display mode
•  The climate control unit detects present and past malfunctions in the control system circuits (open/short circuits) and indicates the DTCs shown in the table on the Mazda Modular Diagnostic System (M-MDS).
•  Clear past malfunctions after completing repairs because once a past malfunction is stored, it will remain stored even after the malfunction has been repaired.
•  The stored past malfunction can be cleared by connecting the Mazda Modular Diagnostic System (M-MDS) to the DLC-2 and operating it.

DTC table

X: Applicable
—: Not applicable

DTC No.

Warning/indicator light

System malfunction location

Fail-safe function

Drive cycle

Self test type*1

Memory function

B1081:71
L.H.D.:
•  Driver-side air mix actuator motor lock
R.H.D.:
•  Passenger-side air mix actuator motor lock
X
C
X
B1082:71
L.H.D.:
•  Passenger-side air mix actuator motor lock
R.H.D.:
•  Driver-side air mix actuator motor lock
X
C
X
B1086:71
Airflow mode actuator motor lock
X
C
X
B10FB:71
Air intake actuator motor lock
X
C
X
B11F0:12
Air intake actuator (potentiometer) circuit short to power supply
X
C, D
X
B11F0:13
Air intake actuator (potentiometer) circuit open
X
C, D
X
B11F5:86*2
Invalid data (humidity sensor temperature) received from humidity sensor
X
C, D
X
B1A61:11
Cabin temperature sensor circuit short to ground
X
C, D
X
B1A61:13
Cabin temperature sensor circuit open
X
C, D
X
B1A63:12
Solar radiation sensor (RH) circuit short to power supply
X
C, D
X
B1A63:13
Solar radiation sensor (RH) circuit open
X
D
X
B1A64:12
Solar radiation sensor (LH) circuit short to power supply
X
C, D
X
B1A64:13
Solar radiation sensor (LH) circuit open
X
D
X
B1A69:86*2
Invalid data (relative humidity) received from humidity sensor
X
C, D
X
B1B71:11
Evaporator temperature sensor circuit short to ground
X
C, D
X
B1B71:13
Evaporator temperature sensor circuit open
X
C, D
X
B1C1A:12
L.H.D.:
•  Driver-side air mix actuator (potentiometer) circuit short to power supply
R.H.D.:
•  Passenger-side air mix actuator (potentiometer) circuit short to power supply
X
C, D
X
B1C1A:13
L.H.D.:
•  Driver-side air mix actuator (potentiometer) circuit open
R.H.D.:
•  Passenger-side air mix actuator (potentiometer) circuit open
X
C, D
X
B1C1B:12
L.H.D.:
•  Passenger-side air mix actuator (potentiometer) circuit short to power supply
R.H.D.:
•  Driver-side air mix actuator (potentiometer) circuit short to power supply
X
C, D
X
B1C1B:13
L.H.D.:
•  Passenger-side air mix actuator (potentiometer) circuit open
R.H.D.:
•  Driver-side air mix actuator (potentiometer) circuit open
X
C, D
X
B1C1C:12
Airflow mode actuator (potentiometer) circuit short to power supply
X
C, D
X
B1C1C:13
Airflow mode actuator (potentiometer) circuit open
X
C, D
X
U0010:88
Unit communication error (MS-CAN)
C
X
U0155:00
Communication error with instrument cluster
X
C, D
X
U0423:68
Invalid date received from Instrument cluster
X
C, D
X
U200D:11
Climate control unit circuit voltage (+5V) circuit short to ground
C, D
X
U210A:86*2
Invalid data (windshield temperature) received from humidity sensor
X
C, D
X
U2300:54
Configuration error (data not received)
X
C, D
X
U2300:55
Configuration error (not configured)
X
C, D
U2300:56
Configuration error (ineffective/non-interchangeable data read)
X
C, D
X
U2300:64
Configuration error (error value read)
X
C, D
X
U3003:16
Climate control unit power supply circuit voltage below threshold (10 V or less)
C, D
X
U3003:17
Climate control unit power supply circuit voltage above threshold (17.3 V or more)
C, D
X
U300E:13
Climate control unit power supply circuit open (IG1 or IG2)
C, D
X

*1  :C: CMDTC self test, D: ODDTC self test
*2  :With humidity sensor
DTC 7-digit code definition
•  When related systems or components have failed, the CM stores the DTC of the malfunctioning part in the CM memory, and allows for the retrieval of the stored data using the scanning tool when necessary. The DTCs are indicated using seven digits. Each digit indicates the following.
ac5wzn00001320
Status byte for DTC
•  The status byte is the two digits (after hyphen) after the 7-digit DTC.
ac5wzn00001326
•  The status byte is a code which indicates the pending code, current/past malfunction status, or warning illumination status.
•  The status byte can be read by performing a CMDTC self-test using the Mazda Modular Diagnostic System (M-MDS).
•  For details on the status byte, refer to the explanation on the Mazda Modular Diagnostic System (M-MDS) when reading the DTC.


PID/data monitor

•  The PID/data monitor function is used for optionally selecting input signal monitor items preset in the climate control unit and reading them out in real-time.


PID/data monitor table

With DUAL switch

PID

Unit/Condition

Data contents

Climate control unit terminal

A/C_SW
Off/On
•  Off: A/C switch is off.
•  On: A/C switch is on.
AUTO_SW
Off/On
•  Off: AUTO switch is off.
•  On: AUTO switch is on.
B_MT_RLY_CS
Off/On
•  Off: Blower relay is off.
•  On: Blower relay is on.
DEF_SW
Off/On
•  Off: DEFROSTER switch is off.
•  On: DEFROSTER switch is on.
DUAL_SW
Off/On
•  Off: DUAL switch is off.
•  On: DUAL switch is on.
ENG_C_TMP
°C, °F
Engine coolant temperature is displayed.
EVA_TMP_SEN
°C, °F
Evaporator temperature is displayed.
1E
F_REC_CS
Off/On
•  Off: Forced recirculate control is off.
•  On: Forced recirculate control is on.
F_WIND_TEMP*1
°C, °F
Windshield temperature is displayed.
FRE_SW
Off/On
•  Off: FRESH switch is off.
•  On: FRESH switch is on.
FUEL_TYPE
Fuel type is displayed.
HC_TMP_SEN
°C, °F
Heater core temperature is displayed.
HUMIDITY_SEN*1
%
Relative humidity is displayed.
INC_TMP_SEN
°C, °F
Cabin temperature is displayed.
1A
M_DOWN_SW
Off/On
•  Off: MODE switch (DOWN) is off.
•  On: MODE switch (DOWN) is on.
M_UP_SW
Off/On
•  Off: MODE switch (UP) is off.
•  On: MODE switch (UP) is on.
OFF_SW
Off/On
•  Off: OFF switch is off.
•  On: OFF switch is on.
OUT_CAR_TMP
°C, °F
Ambient temperature is displayed.
R/DEF_CS
Off (enable)/
Off (suspend)/
Off (inhibit)/
On
•  Off (enable): Rear window defogger is off (operation enabled).
•  Off (suspend): Rear window defogger is off (operation interrupted / indicator is kept On).
•  Off (inhibit): Rear window defogger is off (operation disabled / indicator is turned Off).
•  On: Rear window defogger is on.
R/DEF_SW
Off/On
•  Off: Rear window defogger switch is off.
•  On: Rear window defogger switch is on.
REC_SW
Off/On
•  Off: RECIRCULATE switch is off.
•  On: RECIRCULATE switch is on.
RLS_TEMP*1
°C, °F
Humidity sensor temperature is displayed.
SLR_R_SEN_L
W/m2
Solar radiation amount is displayed.
1H
SLR_R_SEN_R
1F
STOP_ST
Available/
Not Available/
Error
•  Available: i-stop permit request signal is sent.
•  Not Available: i-stop inhibit request is sent.
•  Error: i-stop signal error is sent.
UNIT_TMP
deg_C/deg_F
Unit of temperature is displayed.
•  deg_C: Centigrade is selected.
•  deg_F: Fahrenheit is selected.

*1  :With humidity sensor

With SYNC switch

PID

Unit/Condition

Data contents

Climate control unit terminal

A/C_SW
Off/On
•  Off: A/C switch is off.
•  On: A/C switch is on.
AUTO_SW
Off/On
•  Off: AUTO switch is off.
•  On: AUTO switch is on.
B_MT_RLY_CS
Off/On
•  Off: Blower relay is off.
•  On: Blower relay is on.
DEF_SW
Off/On
•  Off: DEFROSTER switch is off.
•  On: DEFROSTER switch is on.
DUAL_SW
Off/On
•  Off: DUAL switch is off.
•  On: DUAL switch is on.
FAN_DWN_SW
Off/On
•  Off: Airflow volume control switch (DOWN) is off.
•  On: Airflow volume control switch (DOWN) is on.
FAN_UP_SW
Off/On
•  Off: Airflow volume control switch (UP) is off.
•  On: Airflow volume control switch (UP) is on.
ENG_C_TMP
°C, °F
Engine coolant temperature is displayed.
EVA_TMP_SEN
°C, °F
Evaporator temperature is displayed.
1E
F_REC_CS
Off/On
•  Off: Forced recirculate control is off.
•  On: Forced recirculate control is on.
F_WIND_TEMP*1
°C, °F
Windshield temperature is displayed.
FRE_SW
Off/On
•  Off: FRESH switch is off.
•  On: FRESH switch is on.
FUEL_TYPE
Fuel type is displayed.
HC_TMP_SEN
°C, °F
Heater core temperature is displayed.
HUMIDITY_SEN*1
%
Relative humidity is displayed.
INC_TMP_SEN
°C, °F
Cabin temperature is displayed.
1A
M_DOWN_SW
Off/On
•  Off: MODE switch is off.
•  On: MODE switch is on.
ON/OFF_SW
Off/On
•  Off: Power switch is off.
•  On: Power switch is on.
OUT_CAR_TMP
°C, °F
Ambient temperature is displayed.
R/DEF_CS
Off (enable)/
Off (suspend)/
Off (inhibit)/
On
•  Off (enable): Rear window defogger is off (operation enabled).
•  Off (suspend): Rear window defogger is off (operation interrupted / indicator is kept On).
•  Off (inhibit): Rear window defogger is off (operation disabled / indicator is turned Off).
•  On: Rear window defogger is on.
R/DEF_SW
Off/On
•  Off: Rear window defogger switch is off.
•  On: Rear window defogger switch is on.
REC_SW
Off/On
•  Off: RECIRCULATE switch is off.
•  On: RECIRCULATE switch is on.
RLS_TEMP*1
°C, °F
Humidity sensor temperature is displayed.
SLR_R_SEN_L
W/m2
Solar radiation amount is displayed.
1H
SLR_R_SEN_R
1F
S_HT_CUT_CS*2
No_Request/Cut
•  No_Request: Temperature around the seat does not reach approx. 44°C {111°F}.
•  Cut: Temperature around the seat reaches approx. 44°C {111°F}.
1X
ST_HT_SW_D*2
Off/On
•  Off: Seat warmer switch (driver-side) is off.
•  On: Seat warmer switch (driver-side) is on.
1X
ST_HT_SW_P*2
Off/On
•  Off: Seat warmer switch (passenger-side) is off.
•  On: Seat warmer switch (passenger-side) is on.
1X
STOP_ST
Available/
Not Available/
Error
•  Available: i-stop permit request signal is sent.
•  Not Available: i-stop inhibit request is sent.
•  Error: i-stop signal error is sent.
SV_ST_D*3
OFF/Low/Mid/High
•  OFF: Seat ventilation (driver-side) is off.
•  Low: Intake air amount level (driver-side) is low.
•  Mid: Intake air amount level (driver-side) is middle.
•  High: Intake air amount level (driver-side) is high.
1X
SV_ST_P*3
OFF/Low/Mid/High
•  OFF: Seat ventilation (passenger-side) is off.
•  Low: Intake air amount level (passenger-side) is low.
•  Mid: Intake air amount level (passenger-side) is middle.
•  High: Intake air amount level (passenger-side) is high.
1X
SV_SW_D*3
Off/On
•  Off: Seat ventilation switch (driver-side) is off.
•  On: Seat ventilation switch (driver-side) is on.
1X
SV_SW_P*3
Off/On
•  Off: Seat ventilation switch (passenger-side) is off.
•  On: Seat ventilation switch (passenger-side) is on.
1X
SYNC_SW
Off/On
•  Off: SYNC switch is off.
•  On: SYNC switch is on.
1X
UNIT_TMP
deg_C/deg_F
Unit of temperature is displayed.
•  deg_C: Centigrade is selected.
•  deg_F: Fahrenheit is selected.

*1  :With humidity sensor
*2  :With front seat warmer system
*3  :With seat ventilation system


A/C operation check mode

•  The A/C operation check mode forcibly operates the output devices as shown in the operation check table regardless of the signals input to the climate control unit.
•  During an A/C operation check mode operation, indication in the display panel and the illumination of the indicator light on the switches are automatically controlled.
•  Determine the malfunctioning part by visual inspection, listening to the operation sound, placing a hand on the air vents, or checking that each transition is as indicated in the operation check table.

Mazda Modular Diagnostic System (M-MDS) display

Target part

Reference

Air Mix Actuator
•  Air mix actuator
•  Air mix door
Air conditioning compressor
•  A/C compressor
Air Intake Actuator
•  Air intake actuator
•  Air intake door
Blower Motor Speed
•  Blower motor
Airflow Mode Actuator
•  Airflow mode actuator
•  Airflow mode door
Illumination Of All Indicator Lights
•  Climate control unit


Air mix actuator

Operation

Step

Air mix actuator

Airflow mode actuator

Blower speed

Magnet clutch

Air intake actuator

1
0 %
VENT
5th
ON
FRESH
2
100 %

Display

Step

Temperature (°C {°F})

Airflow mode

Blower volume

A/C

Recirculate switch indicator light

Fresh switch indicator light

Defroster switch indicator light

Rear window defogger switch indicator light

1
20.0 {68}
Displayed
Not illuminated
Illuminated
Not illuminated
Not illuminated
2
21.0 {70}

Note
•  After approx. 22 s have elapsed, the operation step moves to the next step.
•  When the last step is finished, the operation is repeated from Step 1.
•  To prevent super-cooling, the magnetic clutch turns off despite the A/C forced override.


A/C compressor

Operation

Step

Air mix actuator

Airflow mode actuator

Blower speed

Magnet clutch

Air intake actuator

1
0 %
VENT
5th
ON
FRESH
2
OFF

Display

Step

Temperature (°C {°F})

Airflow mode

Blower volume

A/C

Recirculate switch indicator light

Fresh switch indicator light

Defroster switch indicator light

Rear window defogger switch indicator light

1
4 {39}
Displayed
Not illuminated
Illuminated
Not illuminated
Not illuminated
2
Not displayed

Note
•  After the following times have elapsed, the operation step moves to the next step.
―  Step 1: Approx. 5 s
―  Step 2: Approx. 25 s
•  When the last step is finished, the operation is repeated from Step 1.


Air intake actuator

Operation

Step

Air mix actuator

Airflow mode actuator

Blower speed

Magnet clutch

Air intake actuator

1
0 %
VENT
5th
ON
Fresh
2
Recirculate (25 %)
3
Recirculate (50 %)
4
Recirculate (75 %)
5
Recirculate (100 %)
6
OFF
Recirculate (75 %)
7
Recirculate (50 %)
8
Recirculate (25 %)
9
Fresh

Display

Step

Temperature (°C {°F})

Airflow mode

Blower volume

A/C

Recirculate switch indicator light

Fresh switch indicator light

Defroster switch indicator light

Rear window defogger switch indicator light

1
4 {39}
Displayed
Not illuminated
Illuminated
Not illuminated
Not illuminated
2
3
4
5
Illuminated
Not illuminated
6
Not displayed
Not illuminated
Illuminated
7
8
9

Note
•  After approx. 2 s have elapsed, the operation step moves to the next step.
•  When the last step is finished, the operation is repeated from Step 1.
•  To prevent super-cooling, the magnetic clutch turns off despite the A/C forced override.


Blower motor

Operation

Step

Air mix actuator

Airflow mode actuator

Blower speed

Magnet clutch

Air intake actuator

1
50 %
VENT
OFF
OFF
FRESH
2
1st
ON
3
3rd
4
5th
5
7th

Display

Step

Temperature (°C {°F})

Airflow mode

Blower volume

A/C

Recirculate switch indicator light

Fresh switch indicator light

Defroster switch indicator light

Rear window defogger switch indicator light

1
1 {34}
Not displayed
Not displayed
Not illuminated
Illuminated
Not illuminated
Not illuminated
2
Displayed
3
4
5

Note
•  After approx. 4 s have elapsed, the operation step moves to the next step.
•  When the last step is finished, the operation is repeated from Step 1.
•  To prevent super-cooling, the magnetic clutch turns off despite the A/C forced override.


Airflow mode actuator

Operation

Step

Air mix actuator

Airflow mode actuator

Blower speed

Magnet clutch

Air intake actuator

1
50 %
VENT
5th
ON
FRESH
2
BI-LEVEL
3
HEAT
4
DEF/HEAT
5
DEFROSTER

Display

Step

Temperature (°C {°F})

Airflow mode

Blower volume

A/C

Recirculate switch indicator light

Fresh switch indicator light

Defroster switch indicator light

Rear window defogger switch indicator light

1
3 {37}
Displayed
Not illuminated
Illuminated
Not illuminated
Not illuminated
2
3
4
5

Note
•  After approx. 11 s have elapsed, the operation step moves to the next step.
•  When the last step is finished, the operation is repeated from Step 1.
•  To prevent super-cooling, the magnetic clutch turns off despite the A/C forced override.


Indicator light

Operation

Step

Air mix actuator

Airflow mode actuator

Blower speed

Magnet clutch

Air intake actuator

50 %
VENT
OFF
OFF
FRESH

Display

Step

Temperature (°C {°F})

Airflow mode

Blower volume

A/C

Recirculate switch indicator light

Fresh switch indicator light

Defroster switch indicator light

Rear window defogger switch indicator light

All indicator displayed
Illuminated
Illuminated
Illuminated
Illuminated


A/C operation check stop

Note
•  If "Stop" is selected while the A/C operation check is operating, the A/C stops at the conditions shown in the table.

Operation

Step

Air mix actuator

Airflow mode actuator

Blower speed

Magnet clutch

Air intake actuator

50 %
VENT
OFF
OFF
FRESH

Display

Step

Temperature (°C {°F})

Airflow mode

Blower volume

A/C

Recirculate switch indicator light

Fresh switch indicator light

Defroster switch indicator light

Rear window defogger switch indicator light

0 {32}
Not displayed
Not displayed
Not illuminated
Illuminated
Not illuminated
Not illuminated