PID/DATA MONITOR TABLE [360°VIEW MONITOR CONTROL MODULE]


id1502c7056800

PID

Unit/Operation

Data contents

Module control terminal

CAM_BACK
NORMAL/Fail
•  NORMAL:Image signal received from rear mount camera is normal.
•  Fail:Normal image signal from rear mount camera cannot be received.
U, W, X, V
CAM_FRONT
NORMAL/Fail
•  NORMAL:Image signal received from front camera is normal.
•  Fail:Normal image signal from front camera cannot be received.
Q, S, T, R
CAM_LEFT
NORMAL/Fail
•  NORMAL:Image signal received from side camera (LH) is normal.
•  Fail:Normal image signal from side camera (LH) cannot be received.
Y, AA, AB, Z
CAM_RIGHT
NORMAL/Fail
•  NORMAL:Image signal received from side camera (RH) is normal.
•  Fail:Normal image signal from side camera (RH) cannot be received.
M, O, P, N
VMC_SW
Off/On
•  Off:360°view monitor switch is not pressed.
•  On:360°view monitor switch is pressed.
AE, AF
VPWR
V
Displays the power supply voltage.
A
VPWR_ST
NORMAL/Fail
•  NORMAL:Power supply status to camera is normal.
•  Fail:Power supply status to camera is not normal.
U, Q, Y, M