BATTERY INSPECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)]
id0117i08006i1
Electrolyte Specific Gravity
1. Measure the electrolyte specific gravity using a hydrometer.
Battery Voltage
1. Inspect the battery as follows:
Step |
Inspection |
Results |
Action |
---|---|---|---|
1
|
Measure the battery positive voltage.
|
12.4 V or more
|
Go to Step 3.
|
Less than 12.4 V
|
Go to the next step.
|
||
2
|
Quick charge for 30 min and recheck voltage.
|
12.4 V or more
|
Go to the next step.
|
Less than 12.4 V
|
Replace the battery.
|
||
3
|
Using the battery load tester, apply load current (see battery load test current) and record battery voltage after 15 s. Is voltage more than the specification?
|
Yes
|
Normal
|
No
|
Replace the battery.
|
Standard specification
Battery temp. (°C {°F}) |
Minimum voltage (V) |
---|---|
4 {39}
|
9.3
|
10 {50}
|
9.4
|
16 {61}
|
9.5
|
21 {70}
|
9.6
|
Parasitic Draw
1. Verify that the ignition is off (lock) and that all doors are closed.
2. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)])
3. Connect the tester between the negative battery terminal and negative battery cable, leave the battery undisturbed for 40 min or more, and then measure the parasitic draw.