BLOW-BY-HEATER RELAY [SKYACTIV-D 2.2]


id0140z7258700


Purpose/Function

•  Supplies power to blow-by heater.
•  Supplies battery voltage to blow-by heater based on the signals from the PCM.

Construction

•  Installed to the relay and fuse block.
ac5wzn00002368

Operation

•  The contact point is on when the battery voltage is supplied to the coil based on the signal from the PCM, and the battery voltage is supplied to the blow-by heater.
ac5wzn00002369

Fail-safe

•  Function not equipped.