DTC U2300:41 [INSTRUMENT CLUSTER]
id0902e8016700
System malfunction location |
Instrument cluster configuration error |
---|---|
Detection condition
|
• Instrument cluster configuration error (data error) detected.
|
Fail-safe
|
—
|
Possible cause
|
• Instrument cluster configuration error
• Instrument cluster malfunction
|
System wiring diagram
|
—
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
PERFORM INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA)
• Using the M-MDS, perform the instrument cluster configuration using the As-Built data.
• Clear DTC for the instrument cluster using the M-MDS.
• Perform the DTC inspection for the instrument cluster using the M-MDS.
• Is the DTC U2300:41 displayed?
|
Yes
|
Using the M-MDS, re-perform the instrument cluster configuration using the As-Built data, then go to the next step.
|
No
|
Go to Step 3.
|
||
2
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Clear DTC for the instrument cluster using the M-MDS.
• Perform the DTC inspection for the instrument cluster using the M-MDS.
• Is the DTC U2300:41 displayed?
|
Yes
|
Replace the instrument cluster, then go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|