ADVANCED KEYLESS ENTRY SYSTEM DOES NOT OPERATE [SECURITY AND LOCKS]
id0903k7012100
Description
Possible cause
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
DETERMINE IF MALFUNCTION CAUSE IS DOOR LOCK
• Refer to "door lock does not operate" symptom troubleshooting and perform the inspection.
• Is the advanced keyless entry system operating normally?
|
Yes
|
Troubleshooting completed. (Explain the contents of the servicing to the customer.)
|
No
|
Go to the next step.
|
||
2
|
VERIFY IF MALFUNCTION CAUSE IS OPERATION OTHER THAN OPERATION PERMISSION CONDITION
• Verify the advanced keyless operation by operating each request switch and the liftgate opener switch with all the following conditions met.
• Is the advanced keyless entry system operating normally?
|
Yes
|
System is normal. (Explain to customer about operation range of advanced keyless entry system)
|
No
|
Go to the next step.
|
||
3
|
VERIFY MALFUNCTION SYMPTOM
• Does the liftgate open using the liftgate opener switch operation?
|
Yes
|
Go to Step 6.
|
No
|
Go to the next step.
|
||
4
|
DETERMINE IF MALFUNCTION CAUSE IS LIFTGATE OPENER SWITCH
• Measure the voltage at rear body control module (RBCM) terminal 4M.
• Is the voltage normal?
Specification
|
Yes
|
Go to Step 11.
|
No
|
Go to the next step.
|
||
5
|
INSPECT IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN REAR BODY CONTROL MODULE (RBCM) AND LIFTGATE OPENER SWITCH
• Disconnect the negative battery cable.
• Disconnect the rear body control module (RBCM) and liftgate opener switch connector.
• Inspect for continuity between the following terminals (vehicle wiring harness).
• Is there continuity?
|
Yes
|
• Inspect the liftgate opener switch. If there is any malfunction, replace it.
• If the liftgate opener switch inspection is normal, inspect or repair the following:
• After repair procedure, go to Step 11.
|
No
|
• Repair or replace the wiring harness for an open circuit.
• After repair procedure, go to Step 11.
|
||
6
|
VERIFY MALFUNCTION SYMPTOM
• Connect the negative battery cable.
• Verify the lock/unlock operation for all doors and liftgate using the request switch operation.
• Is door locked/unlocked?
|
Yes
|
Go to Step 11.
|
No
|
Go to the next step.
|
||
7
|
INSPECT IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN START STOP UNIT AND DOOR LOCK LINK SWITCH (DRIVER-SIDE)
• Disconnect the negative battery cable.
• Disconnect the start stop unit and the front door latch and lock actuator (driver's side) connector.
• Inspect for continuity between the following terminals (vehicle wiring harness).
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
• Repair or replace the wiring harness for an open circuit.
• After repair procedure, go to Step 11.
|
||
8
|
INSPECT IF MALFUNCTION CAUSE IS SHORT TO GROUND IN WIRING HARNESS BETWEEN START STOP UNIT AND DOOR LOCK LINK SWITCH (DRIVER-SIDE)
• Verify that the start stop unit connector is disconnected.
• Inspect for continuity between the following wiring harness terminals (vehicle wiring harness side) and body ground.
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
• Repair or replace the wiring harness for an open circuit.
• After repair procedure, go to Step 11.
|
||
9
|
INSPECT IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN START STOP UNIT AND GROUND
• Verify that the start stop unit connector is disconnected.
• Inspect for continuity between the following terminals (vehicle wiring harness).
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
• Repair or replace the wiring harness for an open circuit.
• After repair, go to Step 11.
|
||
10
|
INSPECT IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN REQUEST SWITCH AND LF CONTROL UNIT
• Disconnect the LF control unit and request switch connector.
• Inspect for continuity between the following terminals (vehicle wiring harness).
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
• Repair or replace the wiring harness for an open circuit.
• After repair, go to the next step.
|
||
11
|
VERIFY IF MALFUNCTION CAUSE WAS CORRECTED
• Does the advanced keyless entry system operate normally?
|
Yes
|
Troubleshooting completed. (Explain the contents of the servicing to the customer.)
|
No
|
If the malfunction has not been resolved, repeat the inspection from Step 1.
|