DTC U0423:00/U0443:00 [DSC HU/CM]


id040262905300

DTC
U0423:00/U0443:00
Abnormal message from instrument cluster
DETECTION CONDITION
•  Correct data cannot be received from instrument cluster
FAIL-SAFE FUNCTION
Refer to “DTC Table” and “Fail-safe function table”. (See DTC TABLE [DSC HU/CM].)
POSSIBLE CAUSE
•  Instrument cluster malfunction
SYSTEM WIRING DIAGRAM
Not applicable

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT FOR INSTRUMENT CLUSTER MALFUNCTION
•  Switch the ignition off.
•  Using the M-MDS, perform the DTC inspection for the instrument cluster.
•  Are any DTCs detected?
Yes
Go to applicable DTC inspection.
No
Go to the next step.
2
VERIFY THAT THE SAME DTC IS NOT PRESENT
•  Using the M-MDS, clear the DTC from the DSC HU/CM.
•  Retrieve the DSC HU/CM DTCs using the M-MDS.
•  Are the same DTCs present?
Yes
Repeat the inspection from Step 1.
If the malfunction recurs, replace the instrument cluster, then go to the next step.
No
Go to the next step.
3
VERIFY THAT NO OTHER DTCS ARE PRESENT
•  Are any other DTCs output?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.