OIL CONTROL VALVE (OCV) INSPECTIONSM1690367
OIL CONTROL VALVE (OCV) INSPECTION

id011000506100


Coil Resistance Inspection

1.Measure the coil resistance between terminals A and B using a tester.

• If it is not within the specification, replace the oil control valve.
beltze00000084
Oil control valve coil resistance
6.9—7.9 ohms [20°C {68°F}]


Spool Valve Operation Inspection

1.Verify that the spool valve inside the oil control valve is at the maximum valve timing retard position as shown in the figure.

• If there is any malfunction, replace the oil control valve.
b3e0110e090

2.Apply battery positive voltage between the oil control valve terminals A and B and verify that the spool valve operates and move to the maximum valve timing advance position.

• If there is any malfunction, replace the oil control valve.
b3e0110e091
Note
• When applying battery positive voltage between the oil control valve terminals, the connection of the positive and negative cables can be either terminal A or B.

3.Stop applying battery positive voltage and verify that the spool valve returns to the maximum valve timing retard position.

• If there is any malfunction, replace the oil control valve.