VARIABLE INTAKE AIR SYSTEM OPERATION [L5]SM1934404
VARIABLE INTAKE AIR SYSTEM OPERATION [L5]

id0113a5147100


Operation Condition

• For the operation condition, refer to CONTROL SYSTEM,VARIABLE INTAKE AIR CONTROL. (See VARIABLE INTAKE AIR CONTROL OPERATION [L5].)

At The Operation Condition

• The variable intake air shutter valve is open.
• Under this condition, the effective intake manifold length is from the intake valve to the chamber (B—C). The intake air inertia effect is obtained at high engine speeds due to this shortened intake air pipe. This increases the intake airflow amount in the cylinder, and higher torque at high engine speeds is obtained.
am3uun00000281

At Non-opening Condition

• Intake manifold vacuum is applied to the variable intake air shutter valve actuator by the operation of the variable intake air solenoid valve, closing the variable intake air shutter valve.
• Under this condition, the effective intake manifold length is from the intake valve to the dynamic chamber (A—C). An inertia charging effect is obtained due to this elongated intake manifold length, air intake volume increases, and higher torque is obtained at low to medium engine speeds.
am3uun00000432