BAROMETRIC PRESSURE (BARO) SENSOR CONSTRUCTION/OPERATION [L3 Turbo]SM1934731
BAROMETRIC PRESSURE (BARO) SENSOR CONSTRUCTION/OPERATION [L3 Turbo]

id0140b6172900

• The BARO sensor is integrated with PCM.
• The piezoelectric element is enclosed in the sensor and the electric potential difference changes as the BARO drops. The output voltage decreases as the BARO decreases.

BARO sensor characteristic

am3uun00000389