AIR FUEL RATIO (A/F) SENSOR, HEATED OXYGEN SENSOR (HO2S) HEATER CONTROL OPERATION [L3 Turbo]SM1934758
AIR FUEL RATIO (A/F) SENSOR, HEATED OXYGEN SENSOR (HO2S) HEATER CONTROL OPERATION [L3 Turbo]

id0140b6782200


Pre-heater Control

Operation condition
• From the engine start to the threshold time: The PCM supplys voltage of approx. 6 V.

Cycle Estimated Control

Operation condition
• The PCM operates the A/F sensor, HO2S when the following conditions are met.

Item

Activation condition

Drive signal

A/F sensor
• After engine start
• After the engine has started and a fixed period of time has elapsed (the elapsed time period after the engine starts is determined by ECT).
• Battery positive voltage is 10 V or more and less than 18 V.
• The PCM outputs a duty signal.
• The element temperature is measured by the impedance of the A/F sensor and a duty ratio is determined.
HO2S
• Starter is off
• After engine start
• After the engine has started and a fixed period of time has elapsed (the time period after the engine starts lengthen if the ECT falls below 0 °C {32 °F}.
• Charging efficiency is the fixed value or less, or during fuel cut.
• The PCM outputs a duty signal. However the duty signal is either 100 % or 0 %.