SCR RELAY CONTROL OPERATION [MZR-CD 2.2]SM1934862
SCR RELAY CONTROL OPERATION [MZR-CD 2.2]
id0140f2116100
• When the ignition is switched ON, the SCR relay turns on and power is supplied to sensors and devices.
• When the ignition is switched from ON to off, an SCR relay-on command signal is received from the SCR control unit.
• When the on-request signal from SCR control unit ends, the SCR relay turns off.