NOX SENSOR ACTIVATION TIMING CONTROL OPERATION [MZR-CD 2.2]SM1934913
NOX SENSOR ACTIVATION TIMING CONTROL OPERATION [MZR-CD 2.2]
id0140f2225200
• The SCR control unit calculates the timing to when the water in the exhaust pipe is gone based on the exhaust gas temperature sensor signal.
• The SCR control unit calculates the point at which the water in the exhaust pipe is gone, and outputs an activation-enable signal.