SCR CONTROL UNIT FUNCTION [MZR-CD 2.2]SM1934954
SCR CONTROL UNIT FUNCTION [MZR-CD 2.2]

id0140f2741700


Function Table

• Control descriptions are as follows:

Function

Contents

Heater control
The tank, pump, and hose of each heater operate to prevent melting and freezing of the AdBlue® according to the ambient and the AdBlue® temperature.
Urea injector control
NOx is reduced by injecting AdBlue® into the exhaust pipe based on the engine operation conditions.
Pump control
Maintains the pressure in the hose after the system operation conditions are met, and collects AdBlue® in the hose and returns it to the urea tank after the engine is stopped.
Remaining amount of AdBlue® detection control
Detects the remaining amount of AdBlue® in the urea tank.
NOx sensor activation timing control
Outputs the activation enabling signal at the point when the water in the exhaust pipe is gone to prevent NOx sensor damage.
SCR relay control
When the ignition is switched ON, the SCR relay is in the on position for a specified time.
CAN
SCR control unit sends and receives signals to and from CAN system related modules through CAN.