Function Table
| Function |
Contents |
|---|---|
|
Heater control
|
The tank, pump, and hose of each heater operate to prevent melting and freezing of the AdBlue® according to the ambient and the AdBlue® temperature.
|
|
Urea injector control
|
NOx is reduced by injecting AdBlue® into the exhaust pipe based on the engine operation conditions.
|
|
Pump control
|
Maintains the pressure in the hose after the system operation conditions are met, and collects AdBlue® in the hose and returns it to the urea tank after the engine is stopped.
|
|
Remaining amount of AdBlue® detection control
|
Detects the remaining amount of AdBlue® in the urea tank.
|
|
NOx sensor activation timing control
|
Outputs the activation enabling signal at the point when the water in the exhaust pipe is gone to prevent NOx sensor damage.
|
|
SCR relay control
|
When the ignition is switched ON, the SCR relay is in the on position for a specified time.
|
|
CAN
|