AIR FUEL RATIO (A/F) SENSOR HEATER CONTROL OPERATION [MZR-CD 2.2]SM1934958
AIR FUEL RATIO (A/F) SENSOR HEATER CONTROL OPERATION [MZR-CD 2.2]

id0140f2780300


Operation Conditions

• The PCM operates the A/F sensor heater when the following conditions are met.

Activation condition

Drive signal

• After the engine has started and a fixed period of time has elapsed (the elapsed time period after the engine starts is determined by exhaust gas temperature).
• Battery positive voltage is 9 V or more and less than 16 V.
• The PCM outputs a duty signal.
• The element temperature is measured by the impedance of the A/F sensor heater and a duty ratio is determined.