id070200100300
Malfunction detection function
Fail-safe function
Fail-safe Function Table
| Part where malfunction is determined |
Malfunction determined when IG SW at ON |
Malfunction already exists when IG SW turned to ON |
|---|---|---|
|
Cabin temperature sensor
|
Cabin temperature sensor input value is fixed at the value right before the malfunction.
|
Cabin temperature sensor input value is fixed at
25 °C {77 °F}.
|
|
Ambient temperature sensor
|
Ambient temperature sensor input value is fixed at the value right before the malfunction.
|
Ambient temperature sensor input value is fixed at
15 °C {59 °F}.
|
|
Evaporator temperature sensor
|
Evaporator temperature sensor input value is fixed at
0 °C {32 °F}.
|
←
|
|
Solar radiation sensor
|
Solar radiation sensor value is fixed at the value right before the malfunction.
|
Solar radiation sensor value is fixed at
0 W/m2.
|
|
Engine coolant temperature sensor
|
Engine coolant temperature sensor input value is fixed at
85 °C {185 °F}.
|
←
|
|
Refrigerant pressure sensor
|
Refrigerant pressure sensor input value is fixed at
0 MPa {0 kgf/cm2, 0 psi}.
|
←
|
|
Air mix actuator
(potentiometer)
|
Air mix actuator drive signal is stopped right when the malfunction is determined.
However, it is fixed at MAX COLD when the manually set temperature is at
15
*1/
18
*2and fixed at MAX HOT when the manually set temperature is at
29
*1/
32
*2.
|
Control based on ambient temperature. (See Graph 1.)
However, it is fixed at MAX COLD when the manually set temperature is at
15
*1/
18
*2 and fixed at MAX HOT when the manually set temperature is at
29
*1/
32
*2.
|
|
Airflow mode actuator
(potentiometer)
|
Airflow mode actuator drive signal is stopped right when the malfunction is determined.
• However, for manual operation using the MODE switch, only vent mode is operable.
• The defroster switch is operable.
|
Control based on ambient temperature. (See Graph 2.)
• However, for manual operation using the MODE switch, only vent mode is operable.
• The defroster switch is operable.
|
|
Air mix actuator
(motor lock)
|
Air mix actuator drive signal is stopped right when the malfunction is determined. After this, a drive signal is output to the air mix actuator and malfunction determination is performed
approx. every 5 min.
|
After the IG SW is at ON, the air mix actuator drive signal is again output normally. After this, a drive signal is output to the air mix actuator and malfunction determination is performed
approx. every 5 min.
|
|
Airflow mode actuator
(motor lock)
|
Airflow mode actuator drive signal is stopped right when the malfunction is determined. After this, a drive signal is output to the airflow mode actuator and malfunction determination is performed
approx. every 5 min.
|
After the IG SW is at ON, the airflow mode actuator drive signal is again output normally. After this, a drive signal is output to the airflow mode actuator and malfunction determination is performed
approx. every 5 min.
|
acxuun00000222
|
Sensor Signal Delay Function
acxuun00000223
|
Memory Function
Display Function
DTC table (climate control system)
| DTC |
Malfunction location |
Detected condition |
Memory function |
|---|---|---|---|
|
B1251
|
Cabin temperature sensor
|
Cabin temperature sensor circuit open
|
X
|
|
B1253
|
Cabin temperature sensor circuit short (body ground)
|
X
|
|
|
B1255
|
Ambient temperature sensor
|
Ambient temperature sensor circuit open
|
X
|
|
B1257
|
Ambient temperature sensor circuit short (body ground)
|
X
|
|
|
B1260
|
Solar radiation sensor
|
Solar radiation sensor circuit short (power supply)
|
X
|
|
B1261
|
Solar radiation sensor circuit short (body ground)
|
—
|
|
|
B1274
|
Airflow mode actuator (potentiometer)
|
Airflow mode actuator (potentiometer) circuit short (power supply)
|
X
|
|
B1275
|
Airflow mode actuator (potentiometer) circuit short (body ground)
|
X
|
|
|
B1282
|
Air mix actuator (potentiometer)
|
Air mix actuator (potentiometer) circuit short (power supply)
|
X
|
|
B1283
|
Air mix actuator (potentiometer) circuit short (body ground)
|
X
|
|
|
B1947
|
Evaporator temperature sensor
|
Evaporator temperature sensor circuit short (body ground)
|
X
|
|
B2014
|
Evaporator temperature sensor circuit open
|
X
|
|
|
B2832
|
Airflow mode actuator (motor lock)
|
Airflow mode actuator motor lock
|
X
|
|
B2834
|
Air mix actuator (motor lock)
|
Air mix actuator motor lock
|
X
|
|
P0532
|
Refrigerant pressure sensor
|
Refrigerant pressure sensor circuit short (body ground)
|
X
|
|
P0533
|
Refrigerant pressure sensor circuit short (power supply)
|
X
|
|
|
U0155
|
CAN communication system
|
Reception error in signal from ICM (HEC)
|
X
|
|
U0516
|
BUS OFF error
|
X
|
DTC table (water heater system)
| DTC |
System malfunction location |
Memory function |
|---|---|---|
|
B102A:11
|
Flame sensor circuit short to ground
|
X
|
|
B102A:15
|
Flame sensor circuit short to power supply or open
|
X
|
|
B1D22:11
|
Coolant temperature sensor circuit short to ground
|
X
|
|
B1D22:15
|
Coolant temperature sensor circuit short to power supply or open
|
X
|
|
B1D22:62
|
Coolant temperature sensor signal compare failure
|
X
|
|
B1D23:11
|
Overheat sensor circuit short to ground
|
X
|
|
B1D23:15
|
Overheat sensor circuit short to power supply or open
|
X
|
|
B1D24:11
|
Glow plug circuit short to ground
|
X
|
|
B1D24:12
|
Glow plug circuit short to power supply
|
X
|
|
B1D24:13
|
Glow plug circuit open
|
X
|
|
B1D25:11
|
Fuel pump (water heater system) circuit short to ground
|
X
|
|
B1D25:12
|
Fuel pump (water heater system) circuit short to power supply
|
X
|
|
B1D25:13
|
Fuel pump (water heater system) circuit open
|
X
|
|
B1D26:11
|
Blower fan circuit short to ground
|
X
|
|
B1D26:12
|
Blower fan circuit short to power supply
|
X
|
|
B1D26:13
|
Blower fan circuit open
|
X
|
|
B1D26:71
|
Blower fan actuator stuck
|
X
|
|
B1D28:4B
|
Fuel pre-heater over temperature
|
X
|
|
B1D29:93
|
No start, even after restart attempt
|
X
|
|
B1D31:94
|
Flame detected prior to normal operation
|
X
|
|
B1D32:92
|
Multiple flame interruption during heating cycle
|
X
|
|
B1D34:66
|
Heater in lock out mode
|
X
|
|
U0010:88
|
Medium speed CAN communication bus off
|
X
|
|
U0155:00
|
Lost communication with instrument cluster
|
X
|
|
U0164:00
|
Lost communication with climate control unit
|
X
|
|
U0423:00
|
Invalid data received from instrument cluster
|
X
|
|
U0424:00
|
Invalid data received from climate control unit
|
X
|
|
U3000:49
|
Internal electronic failure
|
X
|
|
U3000:16
|
Power supply voltage below threshold (less than 10.2V)
|
X
|
|
U3000:17
|
Power supply voltage above threshold (16V or more)
|
X
|
PID/data Monitor Function
PID/data monitor table (climate control system)
| PID name (definition) |
Unit/Condition |
Operation Condition (Reference) |
|---|---|---|
|
DTC_CNT
(Number of continuous DTCs)
|
―
|
Indicates number of DTC
|
PID/data monitor table (water heater system)
| PID Name (Definition) |
Condition/Specification (Reference) |
Unit/Condition |
|---|---|---|
|
HEATER_CORE
(Heater core)
|
• Heater core temperature
|
°C
|
|
EX_TEMP
(Ambient temperature)
|
• External ambient temperature
|
°C
|
|
GLOW_PLUG
(Glow plug)
|
• Glow plug duty cycle
|
%
|
|
START_CNT
(Fuel pump)
|
• Fuel pump start counter
|
—
|
|
COM_BLOWER
(Combustion blower)
|
• Under any condition: B+
|
V
|
|
FUEL_PUMP
(Fuel pump)
|
• Auxiliary heater fuel pump frequency
|
HZ
|
|
OVERHEAT_T
(Overheat sensor)
|
• Auxiliary heater overheat sensor temperature
|
°C
|
|
RPM
(Engine revolutions)
|
• Engine revolutions per minute
|
RPM
|
|
FLAME_TEMP
(Heater flame sensor)
|
• Auxiliary heater flame sensor temperature
|
°C
|
|
COM_AIR_FAN
(Fan Control)
|
• Blower fan is not operating: 0%
• Blower fan is operating: 0-100%
|
On/Off
|
|
GLOW_ON_OFF
(Glow plug)
|
• Glow plug is not operating: Off
• Glow plug is operating: On
|
On/Off
|
|
FUEL_ON_OFF
(Fuel pump)
|
• Fuel pump (water heater unit) is not operating: Off
• Fuel pump (water heater unit) is operating: On
|
On/Off
|
|
PREFILL
(Water heater unit Lock/Unlock Status After Prefilling)
|
• Water heater unit is not operating: Lock
• Water heater unit is operating: Unlock
|
Lock/Unlock
|
Active Command Modes Table
Climate control system
| Command name |
Output part |
Operation |
Operating condition |
|---|---|---|---|
|
MIX_ACT
|
Air Mix Actuator
|
On/Off
|
Ignition switch at ON
|
|
REC/FRESH
|
REC/FRESH Switch
|
||
|
DISPLAY
|
Information Display
|
||
|
BLOWER
|
Blower Motor
|
||
|
MODE_ACT
|
Airflow Mode Actuator
|
A/C Operation Check Mode
| Mazda modular diagnostic system (M-MDS) display |
Target part |
Operation condition |
|---|---|---|
|
Illumination Of All Indicator lights
|
Climate control unit
|
All A/C indicator lights illuminated
|
|
Blower Motor Speed
|
Blower motor
|
|
|
Air mix Actuator
|
Air mix door
|
|
|
Airflow Mode Actuator
|
Airflow mode door
|
|
|
Air Intake Actuator / Air conditioning compressor
|
Air intake door
A/C compressor
|
FRESH ↔ REC
ON ↔ OFF
|