id0102f3166500
| DTC P20E0:00 |
Urea pump pressure sensor circuit high |
|---|---|
|
DETECTION CONDITION
|
• The SCR control unit monitors input voltage from urea pump pressure sensor while the engine switch is on. If the input voltage is
above 3.0 V for 2 sec., the SCR control unit determines that the urea pump pressure sensor circuit voltage is high.
Diagnostic support note
• The MIL illuminates if the SCR control unit detects the above malfunction condition in first drive cycle.
• The SCR warning light flashes if the SCR control unit detects the above malfunction condition in first drive cycle.
• PENDING CODE is available if the SCR control unit detects the above malfunction condition during the first drive cycle.
• FREEZE FRAME DATA (mode2) and snapshot data are available.
• The DTC is stored in the SCR control unit memory.
|
|
POSSIBLE CAUSE
|
• Urea pump pressure sensor short cord connector or terminal malfunction
• SCR control unit connector or terminal malfunction
• Short to power supply in wiring harness between urea pump pressure sensor terminal 1 and SCR control unit terminal 26
• Short to power supply in wiring harness between urea pump pressure sensor terminal 2 and SCR control unit terminal 60
• Open circuit in wiring harness between urea pump pressure sensor terminal 3 and SCR control unit terminal 81
• Urea pump pressure sensor connector or terminal malfunction
• Urea pump pressure sensor malfunction
• SCR control unit malfunction
|
|
|
Diagnostic procedure
| STEP |
INSPECTION |
ACTION |
|
|---|---|---|---|
|
1
|
VERIFY FREEZE FRAME DATA AND DIAGNOSTIC MONITORING TEST RESULTS HAS BEEN RECORDED
• Have FREEZE FRAME DATA (mode2) or snapshot data been recorded?
|
Yes
|
Go to the next step.
|
|
No
|
Record the FREEZE FRAME DATA (mode2) and snapshot data on the repair order, then go to the next step.
|
||
|
2
|
VERIFY RELATED SERVICE INFORMATION AVAILABILITY
• Verify related Service Information availability.
• Is any related Service Information available?
|
Yes
|
Perform the repair or diagnosis according to the available Service Information.
• If the vehicle is not repaired, go to the next step.
|
|
No
|
Go to the next step.
|
||
|
3
|
VERIFY CURRENT SIGNAL STATUS: IS CONCERN INTERMITTENT OR CONSTANT?
• Clear the DTC from the PCM memory using the M-MDS.
• Start the engine.
• Is the PENDING CODE for this DTC present?
|
Yes
|
Go to the next step.
|
|
No
|
Intermittent concern exists.
Perform the “INTERMITTENT CONCERN TROUBLESHOOTING”.
|
||
|
4
|
INSPECT UREA PUMP PRESSURE SENSOR SHORT CORD CONNECTOR FOR POOR CONNECTION
• Switch the ignition off.
• Disconnect the urea pump pressure sensor short cord connector.
• Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
• Is there any malfunction?
|
Yes
|
Repair or replace the terminal, then go to Step 13.
|
|
No
|
Go to the next step.
|
||
|
5
|
INSPECT SCR CONTROL UNIT CONNECTOR FOR POOR CONNECTION
• Switch the ignition off.
• Disconnect the SCR control unit connector.
• Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
• Is there any malfunction?
|
Yes
|
Repair or replace the terminal, then go to Step 13.
|
|
No
|
Go to the next step.
|
||
|
6
|
INSPECT UREA PUMP PRESSURE SENSOR SIGNAL CIRCUIT AND POWER SUPPLY CIRCUITS FOR SHORT TO EACH OTHER
• Urea pump pressure sensor short cord and SCR control unit connectors are disconnected.
• Switch the ignition off.
• Inspect for continuity between urea pump pressure sensor short cord terminals C and D (SCR control unit-side).
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness for a possible short to power supply, then go to Step 13.
|
|
No
|
Go to the next step.
|
||
|
7
|
INSPECT UREA PUMP PRESSURE SENSOR SIGNAL OR POWER CIRCUIT FOR SHORT TO POWER
• Urea pump pressure sensor short cord and SCR control unit connectors are disconnected.
• Switch the ignition ON (Engine off).
• Measure the voltage between the following urea pump pressure sensor terminals and body ground.
• Is there any voltage?
|
Yes
|
Repair or replace the wiring harness for a short to power, then go to Step 13.
|
|
No
|
Go to the next step.
|
||
|
8
|
INSPECT UREA PUMP PRESSURE SENSOR GROUND CIRCUIT FOR OPEN CIRCUIT
• Urea pump pressure sensor short cord and SCR control unit connectors are disconnected.
• Switch the ignition off.
• Inspect for continuity between urea pump pressure sensor short cord terminal E (SCR control unit-side) and SCR control unit terminal 81 (wiring harness-side).
• Is there continuity?
|
Yes
|
Go to the next step.
|
|
No
|
Repair or replace the wiring harness for an open circuit, then go to Step 13.
|
||
|
9
|
INSPECT UREA PUMP PRESSURE SENSOR CONNECTOR FOR POOR CONNECTION
• Urea pump pressure sensor connector is disconnected.
• Switch the ignition off.
• Disconnect the urea pump pressure sensor connector.
• Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
• Is there any malfunction?
|
Yes
|
Repair or replace the terminal, then go to Step 13.
|
|
No
|
Go to the next step.
|
||
|
10
|
INSPECT UREA PUMP PRESSURE SENSOR SIGNAL CIRCUIT AND POWER SUPPLY CIRCUITS FOR SHORT TO EACH OTHER
• Urea pump pressure sensor and short cord connectors are disconnected.
• Switch the ignition off.
• Inspect for continuity between urea pump pressure sensor terminals C and D (urea pump pressure sensor-side).
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness for a possible short to power supply, then go to Step 13.
|
|
No
|
Go to the next step.
|
||
|
11
|
INSPECT UREA PUMP PRESSURE SENSOR SIGNAL OR POWER CIRCUIT FOR SHORT TO POWER
• Urea pump pressure sensor and short cord connectors are disconnected.
• Switch the ignition ON (Engine off).
• Measure the voltage between the following urea pump pressure sensor terminals and body ground.
• Is there any voltage?
|
Yes
|
Repair or replace the wiring harness for a short to power, then go to Step 13.
|
|
No
|
Go to the next step.
|
||
|
12
|
INSPECT UREA PUMP PRESSURE SENSOR GROUND CIRCUIT FOR OPEN CIRCUIT
• Urea pump pressure sensor and short cord connectors are disconnected.
• Switch the ignition off.
• Inspect for continuity between urea pump pressure sensor short cord terminal E (urea pump pressure sensor-side) and SCR control unit terminal 3 (wiring harness-side).
• Is there continuity?
|
Yes
|
Replace the urea pump, then go to the next step. (Urea pump pressure sensor malfunction)
|
|
No
|
Repair or replace the wiring harness for an open circuit, then go to the next step.
|
||
|
13
|
VERIFY TROUBLESHOOTING OF DTC P20E0:00 COMPLETED
• Make sure to reconnect all disconnected connectors.
• Clear the DTC from the SCR control unit memory using the M-MDS.
• Switch the ignition ON for 2 sec.
• Retrieve the DTC using the M-MDS.
• Is the PENDING CODE for this DTC present?
|
Yes
|
Replace the SCR control unit, then go to the next step.
|
|
No
|
Go to the next step.
|
||
|
14
|
VERIFY AFTER REPAIR PROCEDURE
• Perform the “AFTER REPAIR PROCEDURE”. (See
AFTER REPAIR PROCEDURE [MZR-CD 2.2].)
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
(See
DTC TABLE [MZR-CD 2.2].)
|
|
No
|
DTC troubleshooting completed.
|
||