id0103f3820000
| 5 |
SCR WARNING LIGHT ILLUMINATES CONTINUOUSLY |
|---|---|
|
DESCRIPTION
|
• SCR warning light illuminates continuously after engine starts, because of the AdBlue® supply begins to run out.
• Possible travel distance is displayed on AdBlue® gauge.
|
|
POSSIBLE CAUSE
|
• AdBlue® residual quantity in urea tank is low.
• Instrument cluster malfunction
|
Diagnostic Procedure
| STEP |
INSPECTION |
RESULTS |
ACTION |
|---|---|---|---|
|
1
|
Turn on and off all warning light and indicator light using M-MDS active command mode function WL+IL.
Do the SCR warning light turn on and off according to simulation function?
|
Yes
|
Refill the AdBlue® to urea tank till filled up.
|
|
No
|
Replace the instrument cluster.
|
||
|
2
|
Verify test results.
• If normal, return to the diagnostic index to service any additional symptoms. (See
SYMPTOM DIAGNOSTIC INDEX [MZR-CD 2.2].)
• If the malfunction remains, inspect the related Service Information and perform repair or diagnosis.
|
||