id0110a8801400
Coil Resistance Inspection
1.Disconnect the negative battery cable.
2.Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [L5].)
3.Disconnect the OCV connector.
4.Measure the resistance between terminals A and B using an ohmmeter.
am6zzw00001789
|
5.Install in the reverse order of removal.
Spool Valve Operation Inspection
1.Remove the OCV. (See OIL CONTROL VALVE (OCV) REMOVAL/INSTALLATION [L5].)
2.Verify that the spool valve in the OCV is in the maximum valve timing retard position as indicated in the figure.
am3uuw00002261
|
3.Verify that the battery is fully charged. (See BATTERY INSPECTION [L5].)
am6zzw00001789
|
4.Apply battery positive voltage between the OCV terminals and verify that the spool valve operates and moves to the maximum valve timing advance position.
am3uuw00002262
|
5.Stop applying battery positive voltage and verify that the spool valve returns to the maximum valve timing retard position.
6.Install the OCV. (See OIL CONTROL VALVE (OCV) REMOVAL/INSTALLATION [L5].)