id0112b3801800
Part Inspection
1.Verify that the battery is fully charged. (See BATTERY INSPECTION [L3 Turbo].)
2.Remove the charge air cooler duct. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [L3 Turbo].)
3.Disconnect the cooling fan motor connector (2 terminals).
4.Install a tester and battery to the cooling fan motor connector (2 terminals) as shown in the figure.
acxuuw00002065
|
5.Verify that each fan motors operate smoothly at the standard current.