id0113b5801200
Operation Inspection
1.Remove the air hose. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [L3 Turbo].)
2.Disconnect the vacuum hose from the variable swirl control solenoid valve.
3.Connect a vacuum pump to the variable swirl shutter valve actuator.
4.Apply vacuum and verify that the rod moves.
| Vacuum kPa {mmHg, inHg} |
Rod movement |
|---|---|
|
–2.7 {–20, –0.7} or less
|
Not move
|
|
–33.4 {–251, –9.9} or more
|
Fully pulled
|