GUIDE BLADE ACTUATOR INSPECTION [MZR-CD 2.2]SM2444730
GUIDE BLADE ACTUATOR INSPECTION [MZR-CD 2.2]

id0113f3807200

1.Disconnect the vacuum hose from the guide blade actuator.

2.Connect the vacuum pump to the guide blade actuator.

acxwzw00000947

3.Apply vacuum and verify that the rod moves as specified.

• If not as specified, replace the turbocharger. (See EXHAUST SYSTEM REMOVAL/INSTALLATION [MZR-CD 2.2].)

Specification

Vacuum (kPa {mmHg, inHg})

Rod movement

Below –26.0 {–195, –7.68}
Starts to move
Above –48.5 {–364, –14.3}
Fully pulled