id0114z3803200
1.Complete the “BEFORE SERVICE PRECAUTION”. (See BEFORE SERVICE PRECAUTION [L5].)
2.Remove the fuel tank and the fuel pump unit and the fuel gauge sender unit as a single unit. (See FUEL TANK REMOVAL/INSTALLATION [L5].)
3.Perform the following procedure to verify the fuel tank airtightness.
acxuuw00000121
|
4.Plug the fuel pump unit pipe and port C.
acxwzw00000144
|
5.Level the fuel tank.
6.Apply a pressure of 3 kPa {23 mmHg, 0.9 inHg} to port A and wait for a while.
7.With the pressure still applied, verify that there is air flow port B and the pressure is 0—3 kPa {0—23 mmHg, 0—0.9 inHg}.
8.Apply a pressure of -0.5 kPa {-3.8 mmHg, -0.1 inHg} to port A and wait for a while.
9.With the pressure still applied, verify that there is air flow port B and the pressure is -0.5—0 kPa {-3.8—0 mmHg, -0.1—0 inHg}.
10.Apply a pressure to port A and wait for a while.
acxwzw00000145
|
11.With the pressure still applied, verify that there is no air flow from port C.