id0116b4805500
Quick Release Connector Type
acxwzw00000151
|
Type A Removal
1.Rotate the release tab on the quick release connector to the stopper position.
am3uuw00002245
|
2.Pull out the evaporative hose straight from the evaporative pipe and disconnect it.
3.Cover the disconnected quick release connector and evaporative pipe with vinyl sheeting or a similar material to prevent it from scratches or dirt.
Type B Removal
When using SST 49 E042 001
1.Set the SST parallel to the quick release connector.
acxwzw00001573
|
2.Hold the center of the retainer tabs with the SST ends and press the retainer.
3.Pull the connector side and disconnect the quick release connector.
4.Raise a retainer tab using the SST and remove the retainer.
acxwzw00001574
|
5.Cover the disconnected quick release connector and pipe with vinyl sheeting or a similar material to prevent it from scratches or dirt.
When using SST 49 N013 103A (Part of 49 N013 1A0D)
1.Insert the SST into the quick release connector.
acxwzw00001575
|
2.Pull out the hose straight from the pipe and disconnect it.
3.Cover the disconnected quick release connector and pipe with vinyl sheeting or a similar material to prevent it from scratches or dirt.
Type A Installation
acxwzw00001576
|
1.Inspect the evaporative hose and evaporative pipe sealing surface for damaged and deformation.
2.Apply a small amount of clean engine oil to the sealing surface of the evaporative pipe.
3.Reconnect the evaporative hose straight to the evaporative pipe until a click is heard.
4.Lightly pull and push the quick release connector a few times by hand, and then verify that it can move 2.0—3.0 mm {0.08—0.12 in}and is connected securely.
Type B Installation
acxwzw00001577
|
1.Inspect the hose and pipe sealing surface for damage and deformation.
2.Apply a small amount of clean engine oil to the sealing surface of the pipe.
3.Install a new retainer to the quick release connector.
4.Reconnect the hose straight to the pipe until a click is heard.
5.Lightly pull and push the quick release connector a few times by hand, and then verify that it is connected securely.