id0116z3805500
Quick Release Connector Type
acxuuw00004470
|
Type A Removal
When using SST 49 E042 001
1.Set the SST parallel to the quick release connector.
acxwzw00001578
|
2.Hold the center of the retainer tabs with the SST ends and press the retainer.
3.Pull the quick release connector side and disconnect the quick release connector.
4.Raise a retainer tab using the SST and remove the retainer.
acxwzw00001579
|
5.Cover the disconnected quick release connector and evaporative pipe with vinyl sheeting or a similar material to prevent it from scratches or dirt.
When using SST 49 N013 103A (Part of 49 N013 1A0D)
1.Insert the SST into the quick release connector.
am6xuw00001914
|
2.Pull out the evaporative hose straight from the evaporative pipe and disconnect it.
3.Cover the disconnected quick release connector and evaporative pipe with vinyl sheeting or a similar material to prevent it from scratches or dirt.
Type B Removal
1.Move the retainer upward using a small flathead screwdriver or a similar tool.
am6xuw00001374
|
2.Pull out the evaporative hose straight from the evaporative pipe and disconnect it.
3.Cover the disconnected quick release connector and evaporative pipe with vinyl sheeting or a similar material to prevent it from scratches or dirt.
Type A Installation
acxwzw00001580
|
1.Inspect the evaporative hose and evaporative pipe sealing surface for damage and deformation.
2.Apply a small amount of clean engine oil to the sealing surface of the evaporative pipe.
3.Install a new retainer to the quick release connector.
4.Reconnect the hose straight to the pipe until a click is heard.
5.Lightly pull and push the quick release connector a few times by hand, and then verify that it is connected securely.
Type B Installation
1.Inspect the evaporative hose and evaporative pipe sealing surface for damage and deformation.
2.Apply a small amount of clean engine oil to the sealing surface of the evaporative pipe.
3.Install the quick release connector.
am3uuw00004573
|