EXHAUST GAS PRESSURE CORRECTION TEMPERATURE SENSOR INSPECTION [MZR-CD 2.2]SM2444973
EXHAUST GAS PRESSURE CORRECTION TEMPERATURE SENSOR INSPECTION [MZR-CD 2.2]

id0140f2446200

Note
• Perform the following test only when directed.

Resistance Inspection

1.Remove the exhaust gas pressure correction temperature sensor. (See EXHAUST GAS PRESSURE SENSOR/EXHAUST GAS PRESSURE CORRECTION TEMPERATURE SENSOR REMOVAL/INSTALLATION [MZR-CD 2.2].)

2.Place the exhaust gas pressure correction temperature sensor in water with a thermometer, and heat the water gradually.

3.Measure the resistance between the exhaust gas pressure correction temperature sensor terminals using an ohmmeter.

• If not as specified, replace the exhaust gas pressure correction temperature sensor. (See EXHAUST GAS PRESSURE SENSOR/EXHAUST GAS PRESSURE CORRECTION TEMPERATURE SENSOR REMOVAL/INSTALLATION [MZR-CD 2.2].)

Specification

Water temperature (°C {°F})

Resistance (kilohm)

20 {68.EN_UK}
2.21—2.69
80 {176.EN_UK}
0.29—0.35

am6zzw00004019