id0140f2446200
Resistance Inspection
1.Remove the exhaust gas pressure correction temperature sensor. (See EXHAUST GAS PRESSURE SENSOR/EXHAUST GAS PRESSURE CORRECTION TEMPERATURE SENSOR REMOVAL/INSTALLATION [MZR-CD 2.2].)
2.Place the exhaust gas pressure correction temperature sensor in water with a thermometer, and heat the water gradually.
3.Measure the resistance between the exhaust gas pressure correction temperature sensor terminals using an ohmmeter.
Specification
| Water temperature (°C {°F}) |
Resistance (kilohm) |
|---|---|
|
20 {68.EN_UK}
|
2.21—2.69
|
|
80 {176.EN_UK}
|
0.29—0.35
|
am6zzw00004019
|