FUEL TEMPERATURE SENSOR INSPECTION [MZR-CD 2.2]SM2444994
FUEL TEMPERATURE SENSOR INSPECTION [MZR-CD 2.2]

id0140f2806400

Note
• Perform the following test only when directed.

Resistance Inspection

1.Disconnect the negative battery cable.

2.Remove the supply pump. (See SUPPLY PUMP REMOVAL/INSTALLATION [MZR-CD 2.2].)

3.Measure the resistance between the fuel temperature sensor terminals using an ohmmeter.

• If not as specified, repair the supply pump. (See SUPPLY PUMP REMOVAL/INSTALLATION [MZR-CD 2.2].)

Specification

Ambient temperature

(°C {°F})

Resistance (kilohm)

20 {68.EN_UK}
2.32—2.59

am3zzw00005377