id0140f2807600
Voltage Inspection
1.Switch the ignition to ON.
2.Monitor the EGRP PID using the M-MDS.
3.Start the engine and warm up the engine completely.
4.Command the EGRP PID from 0 to 100 % using simulation function.
5.Verify that the EGRP PID reading change according to EGRP commanded value.
EGRP PID (Reference)
| EGR valve position |
Output voltage |
|---|---|
|
Approx. 8 %
|
Approx. 1.1 V
|
|
Approx. 18 %
|
Approx. 1.4 V
|
|
Approx. 27 %
|
Approx. 1.7 V
|