id040200805600
|
DTC
|
B2477
|
DSC HU/CM configuration
|
|
|
DETECTION CONDITION
|
• Condition 1
• Condition 2
• Condition 3
|
||
|
POSSIBLE CAUSE
|
• Module configuration procedure was not completed properly.
• DSC HU/CM malfunction
|
||
Diagnostic procedure
| STEP |
INSPECTION |
ACTION |
|
|---|---|---|---|
|
1
|
VERIFY CONFIGURATION
• Has the DSC HU/CM configuration been performed?
|
Yes
|
Go to the next step.
|
|
No
|
Perform configuration using the M-MDS.
(See
DSC CONFIGURATION.)
|
||
|
2
|
VERIFY DTC TROUBLESHOOTING COMPLETED
• Clear the DTC from the memory. (See
ON-BOARD DIAGNOSIS.)
• Is the same DTC present?
|
Yes
|
Repeat the inspection from Step 1.
If the malfunction recurs, replace the DSC HU/CM, then go to the next step.
|
|
No
|
Go to the next step.
|
||
|
3
|
VERIFY AFTER REPAIR PROCEDURE
• Are any other DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
(See
ON-BOARD DIAGNOSIS.)
|
|
No
|
DTC troubleshooting completed.
|
||