id051721292000
1.Select the selector lever to N position.
2.Disconnect the negative battery cable.
3.Remove the air cleaner component. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [L5].)
4.Remove the under cover.
5.Remove in the order indicated in the table.
am8rrw00002452
|
|
1
|
Connector
|
|
2
|
Clip
|
|
3
|
Selector cable
|
|
4
|
Manual shaft nut
|
|
5
|
Washer
|
|
6
|
Manual shaft lever
|
|
7
|
TR switch
(See
TR switch Installation Note.)
|
6.Install in the reverse order of removal.
7.Inspect the TR switch.
Manual Shaft Nut Removal Note
1.Set the adjustable wrench as shown to hold the manual shaft lever and loosen the manual shaft nut.
am6xuw00001948
|
TR switch Installation Note
1.Verify that the manual shaft is aligned with N position.
am3uuw00002408
|
2.Adjust the TR switch between terminals B and C until the resistance becomes 713—788 ohms.
am8rrw00002338
|
3.Tighten the TR switch installation bolts.
Manual Shaft Nut Installation Note
1.Set the adjustable wrench as shown to hold the manual shaft lever and tighten the manual shaft nut.
am6xuw00001950
|