id051723801300
1.Disconnect the negative battery cable.
2.Remove the air cleaner component. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [L3 Turbo].)
3.Drain the ATF. (See AUTOMATIC TRANSAXLE FLUID (ATF) REPLACEMENT [AW6A-EL, AW6AX-EL].)
4.Remove the control valve body. (See CONTROL VALVE BODY REMOVAL/INSTALLATION [AW6A-EL, AW6AX-EL].)
5.Remove the input/turbine speed sensor.
acxuuw00000501
|
6.Install the input/turbine speed sensor.
7.Install the control valve body. (See CONTROL VALVE BODY REMOVAL/INSTALLATION [AW6A-EL, AW6AX-EL].)
8.Add ATF to the specified level. (See AUTOMATIC TRANSAXLE FLUID (ATF) REPLACEMENT [AW6A-EL, AW6AX-EL].)
9.Install the air cleaner component. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [L3 Turbo].)
10.Connect the negative battery cable.
11.Perform the mechanical system test. (See MECHANICAL SYSTEM TEST [AW6A-EL, AW6AX-EL].)