id070228801700
DTC table (water heater system)
| DTC |
System malfunction location |
Memory function |
Page |
|---|---|---|---|
|
B102A:11
|
Flame sensor circuit short to ground
|
X
|
|
|
B102A:15
|
Flame sensor circuit short to power supply or open
|
X
|
|
|
B1D22:11
|
Coolant temperature sensor circuit short to ground
|
X
|
|
|
B1D22:15
|
Coolant temperature sensor circuit short to power supply or open
|
X
|
|
|
B1D22:62
|
Coolant temperature sensor signal compare failure
|
X
|
|
|
B1D23:11
|
Overheat sensor circuit short to ground
|
X
|
|
|
B1D23:15
|
Overheat sensor circuit short to power supply or open
|
X
|
|
|
B1D24:11
|
Glow plug circuit short to ground
|
X
|
|
|
B1D24:12
|
Glow plug circuit short to power supply
|
X
|
|
|
B1D24:13
|
Glow plug circuit open
|
X
|
|
|
B1D25:11
|
Fuel pump (water heater system) circuit short to ground
|
X
|
|
|
B1D25:12
|
Fuel pump (water heater system) circuit short to power supply
|
X
|
|
|
B1D25:13
|
Fuel pump (water heater system) circuit open
|
X
|
|
|
B1D26:11
|
Blower fan circuit short to ground
|
X
|
|
|
B1D26:12
|
Blower fan circuit short to power supply
|
X
|
|
|
B1D26:13
|
Blower fan circuit open
|
X
|
|
|
B1D26:71
|
Blower fan actuator stuck
|
X
|
|
|
B1D28:4B
|
Fuel pre-heater over temperature
|
X
|
|
|
B1D29:93
|
No start, even after restart attempt
|
X
|
|
|
B1D31:94
|
Flame detected prior to normal operation
|
X
|
|
|
B1D32:92
|
Multiple flame interruption during heating cycle
|
X
|
|
|
B1D34:66
|
Heater in lock out mode
|
X
|
|
|
U0010:88
|
Medium speed CAN communication bus off
|
X
|
|
|
U0155:00
|
Lost communication with instrument cluster
|
X
|
|
|
U0164:00
|
Lost communication with climate control unit
|
X
|
|
|
U0423:00
|
Invalid data received from instrument cluster
|
X
|
|
|
U0424:00
|
Invalid data received from climate control unit
|
X
|
|
|
U3000:49
|
Internal electronic failure
|
X
|
|
|
U3000:16
|
Power supply voltage below threshold (less than 10.2V)
|
X
|
|
|
U3000:17
|
Power supply voltage above threshold (16V or more)
|
X
|