id0702c1812400
|
4
|
No temperature control with climate control unit
|
|
DESCRIPTION
|
• Temperature does not change when operating temperature dial
• Malfunction in A/C unit and/or climate control unit air intake system
|
|
POSSIBLE CAUSE
|
• A/C unit air intake link, air intake crank, air intake rod, malfunction
• Climate control unit rack-and-pinion, air intake wire malfunction
• A/C unit air mixture door malfunction
• Heater piping malfunction
|
Diagnostic procedure
| STEP |
INSPECTION |
ACTION |
|
|---|---|---|---|
|
1
|
INSPECT COOLANT TEMPERATURE
• Is the coolant sufficiently warmed up?
|
Yes
|
Go to the next step.
|
|
No
|
Warm up the engine, then go to Step 8.
|
||
|
2*
|
INSPECT CLIMATE CONTROL UNIT POWER SUPPLY FUSE FOR B+ SIGNAL
• Is the climate control unit power supply fuse for B+ signal normal?.
|
Yes
|
Go to the next step.
|
|
No
|
Inspect for short to GND blown fuse circuit.
Repair or replace as necessary.
Install appropriate amperage fuse.
Then go to Step 20.
|
||
|
3*
|
INSPECT TO SEE WHETHER MALFUNCTION (OPEN CIRCUIT) IS IN B+ SIGNAL WIRING HARNESS (BETWEEN FUSE BLOCK AND CLIMATE CONTROL UNIT) OR ELSEWHERE.
• Disconnect the climate control unit connector (24-pin).
• Switch the ignition to ON.
• Measure voltage at climate control unit harness-side connector (24-pin) terminal 1R (B+ signal).
• Is the voltage
approx. 12V?
|
Yes
|
Go to the next step.
|
|
No
|
Repair wiring harness between fuse block and climate control unit, then go to Step 20.
|
||
|
*4
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND GND) OR ELSEWHERE
• Climate control unit connector (24-pin) disconnected.
• Verify that continuity between climate control unit harness-side connector (24-pin) terminal 1D and GND.
• Is the continuity?
|
Yes
|
Go to the next step.
|
|
No
|
Repair wiring harness between climate control unit and GND.
Inspect the GND point.
Then go to Step 20.
|
||
|
*5
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR AIR MIX ACTUATOR
• Switch the ignition to ON.
• Measure the voltage at climate control unit terminal 1X (24-pin) when temperature control dial at MAX HOT and MAX COLD. (See
CLIMATE CONTROL UNIT INSPECTION [FULL-AUTO AIR CONDITIONER].)
• Is voltage normal?
|
Yes
|
Go to Step 16.
|
|
No
|
Go to the next step.
|
||
|
*6
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN POTENTIOMETER OR ELSEWHERE
• Switch the ignition to ON.
• Measure voltage at climate control unit terminal 1P (24-pin) when airflow mode change to DEFROSTER and VENT. (See
CLIMATE CONTROL UNIT INSPECTION [FULL-AUTO AIR CONDITIONER].)
• Is voltage normal?
|
Yes
|
Go to Step 9.
|
|
No
|
Go to the next step.
|
||
|
*7
|
INSPECT TO SEE WHETHER MALFUNCTION
(LACK OF CONTINUITY OR SHORT TO BATTERY POWER OR GND) IS IN POTENTIOMETER POWER SUPPLY (CLIMATE CONTROL UNIT TERMINAL 1J) OR ELSEWHERE
• Switch the ignition to ON.
• Measure voltage at climate control unit terminal 1J (24-pin).
• Is voltage
approx. 5V?
|
Yes
|
Go to the next step.
|
|
No
|
Repair wiring harness between climate control unit terminal 1J and follows:
• Air mix actuator terminal A
Then go to Step 20.
|
||
|
*8
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY OR OPEN) IS IN POTENTIOMETER GND (CLIMATE CONTROL UNIT TERMINAL 1C) OR ELSEWHERE
• Measure voltage at climate control unit terminal 1C (24-pin).
• Is the voltage
below. 1.0V?
|
Yes
|
Go to Step 12.
|
|
No
|
Repair wiring harness between climate control unit terminal 1C and follows:
• Air mix actuator terminal B
Then go to Step 20.
|
||
|
9
|
INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO POWER) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR ELSEWHERE
• Is climate unit terminal 1X voltage
approx. 12 V, at Step 5?
|
Yes
|
Repair wiring harness for short to power between climate control unit terminal 1X and air mix actuator terminal C.
Then go to Step 20.
|
|
No
|
Go to the next step.
|
||
|
*10
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR ELSEWHERE
• Switch the ignition to off.
• Disconnect the climate control and air mix actuator connectors.
• Verify continuity between climate control unit terminal 1X (24-pin) and air mix actuator terminal C at harness-side connector.
• Is there continuity?
|
Yes
|
Go to the next step.
|
|
No
|
Repair wiring harness between climate control unit terminal 1X and air mix actuator terminal C.
Then go to Step 20.
|
||
|
*11
|
INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO GND) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR POTENTIOMETER COMMON (POWER SUPPLY OR GND) HARNESS
• Verify continuity between climate control unit harness-side connector terminal 1X (24-pin) and GND.
• Is there continuity?
|
Yes
|
Repair wiring harness for short to GND between climate control unit terminal 1X and air mix actuator terminal C.
Then go to Step 20.
|
|
No
|
Inspect and repair for open circuit following:
• Between air mix actuator terminal A and junction point to airflow mode actuator (potentiometer power supply).
• Between air mix actuator terminal B and junction point to airflow mode actuator (potentiometer power GND).
Then go to Step 20.
|
||
|
*12
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN AIR MIX ACTUATOR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR)
• Disconnect the air mix actuator connector.
• Measure voltage at the following terminals of air mix actuator.
• Are voltages as shown below?
|
Yes
|
Go to Step 16.
|
|
No
|
Go to the next step.
|
||
|
*13
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO B+ BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Air mix actuator connector disconnected.
• Disconnect the climate control unit connector.
• Measure voltage at the following terminals of air mix actuator harness-side connector.
• Are the voltage
approx. 0V?
|
Yes
|
Go to the next step.
|
|
No
|
Repair wiring harness between climate control unit and air mix actuator.
Then go to Step 20.
|
||
|
*14
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN AIR MIX ACTUATOR OR ELSEWHERE
• Air mix actuator connector and climate control unit connector disconnected.
• Switch the ignition to off.
• Verify that continuity at the following harness-side connector terminals between air mix actuator and GND.
• Is there continuity?
|
Yes
|
Repair wiring harness for short to GND between climate control unit and air mix actuator.
Then go to Step 20.
|
|
No
|
Go to the next step.
|
||
|
*15
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (OPEN CIRCUIT BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Air mix actuator connector and climate control unit connector disconnected.
• Switch the ignition to off.
• Verify that continuity at the following harness-side connector terminals between air mix actuator and GND.
• Is there continuity?
|
Yes
|
Go to the next step.
|
|
No
|
Repair wiring harness for open circuit between climate control unit and air mix actuator.
Then go to Step 20.
|
||
|
16
|
INSPECT AIR MIX ACTUATOR
• Inspect the air mix actuator. (See
AIR MIX ACTUATOR INSPECTION [FULL-AUTO AIR CONDITIONER].)
• Is air mix actuator normal?
|
Yes
|
Go to the next step.
|
|
No
|
Replace the air mix actuator.
Then go to 20.
|
||
|
17
|
INSPECT AIR MIX LINK
• Inspect air mix links for following.
• Are above items okay?
|
Yes
|
Go to the next step.
|
|
No
|
Apply grease to links.
If any links are damaged. replace malfunctioning part.
Then go to Step 20.
|
||
|
18
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR MIX DOOR ELSEWHERE
• Inspect A/C unit and each-side air mix door.
• Are above items okay?
|
Yes
|
Go to the next step.
|
|
No
|
Remove the obstruction, or install door in proper position.
If any door are cracked, replace them.
Then go to Step 20.
|
||
|
19
|
INSPECT HEATER LINE
• Inspect the heater lines.
• Are the above items normal?
|
Yes
|
Operation is normal. Recheck malfunction symptoms.
|
|
No
|
If heater piping connections are loose, tighten the connections to the specified torque.
Repair or replace the heater piping, then go to the next step.
|
||
|
20
|
VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR
• Does the unit operate in every temperature setting?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.
|
||