1.Set the fan speed MAX HI.
2.Set the temperature control at MAX COLD (Turn the left).
3.Turn the A/C switch off.
4.Set the RECIRCULATE mode.
5.Close all doors and windows.
6.Wait for 5 min.
7.Remove the glove compartment. (See GLOVE COMPARTMENT REMOVAL/INSTALLATION.)
8.Disconnect the evaporator temperature sensor connector.
9.Measure the temperature at the blower inlet.
10.Measure the resistance between terminals of the evaporator temperature sensor.
acxuuw00000978
|