id0740a1801700
1.Connect battery positive voltage to terminal D or F and ground to terminal F or D of the airflow mode actuator.
acxwzw00000701
|
2.Verify that the airflow mode actuator operates as shown below.
acxaaw00000848
|
acxaaw00000849
|
| Connection |
Movement |
|
|---|---|---|
| B+ |
GND |
|
|
D
|
F
|
DEFROSTER → VENT
|
|
F
|
D
|
VENT → DEFROSTER
|
3.Verify that the resistance between the terminals of the airflow mode actuator is as shown in the graph.
acxaaw00001300
|