id0740a1817300
1.Disconnect the negative battery cable.
2.Discharge the refrigerant from the system. (See REFRIGERANT RECOVERY.) (See REFRIGERANT CHARGING.)
3.Loosen the refrigerant pressure sensor using two spanners.
4.Remove in the order indicated in the table.
acxwzw00000712
|
|
1
|
Refrigerant pressure sensor connector
|
|
2
|
Refrigerant pressure sensor
|
5.Install in the reverse order of removal.
6.Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST.)
Refrigerant Pressure Sensor Installation Note
1.Apply compressor oil to O-ring and connect the joint.