AIR INTAKE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]SM2445720
AIR INTAKE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]

id0740a2801500

1.Connect battery positive voltage to terminal D or F and ground to terminal F or D of the air intake actuator.

2.Verify that the air intake actuator operates as shown below.

• If there is any malfunction, replace the air intake actuator.

Connection

Movement

B+

GND

D
F
RECIRCULATE → FRESH
F
D
FRESH → RECIRCULATE

acxwzw00000732
acxwzw00000733