REFRIGERANT PRESSURE SENSOR INSPECTION [MANUAL AIR CONDITIONER]SM2445729
REFRIGERANT PRESSURE SENSOR INSPECTION [MANUAL AIR CONDITIONER]

id0740a2817400

1.Install the manifold gauge.

2.Verify the high-pressure side reading of the manifold gauge.

3.Measure the terminal voltage of the climate control unit.

― E, K and N

4.Verify that below graph as measure the terminal voltage N.

5.Follow the climate control unit inspection when measure the other terminal voltage. (See CLIMATE CONTROL UNIT INSPECTION [MANUAL AIR CONDITIONER].)

• Terminal K: 1.0 V or less
• Terminal E: Approx. 5 V (Ignition switch on)
― If the each voltage is not normal, inspect the related wiring harness.
• If there is any malfunction, replace the related wiring harness.
• If wiring harness is normal, replace the refrigerant pressure sensor.

acxwzw00000744