DTC U0214 [ADVANCED KEYLESS ENTRY AND START SYSTEM]SM2445810
DTC U0214 [ADVANCED KEYLESS ENTRY AND START SYSTEM]

id09021g802900

DTC U0214

Keyless receiver

DETECTION CONDITION
• When the keyless receiver power supply voltage is less than 7.5 V
POSSIBLE CAUSE
• Open or short circuit in wiring harness between keyless control module and keyless receiver
• Keyless receiver malfunction
• Keyless control module malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT WIRING HARNESS BETWEEN KEYLESS RECEIVER AND GROUND
• Disconnect keyless receiver connector.
• Is there continuity between keyless receiver terminal E and ground?
Yes
Go to next step.
No
Repair the wiring harness between the keyless receiver and ground.
Go to next step.
2
INSPECT COMMUNICATION CIRCUIT FOR CONTINUITY
• Disconnect keyless control module connector.
• Inspect the wiring harness between keyless receiver terminal A and keyless control module terminal 3A, and keyless receiver terminal C and keyless control module terminal 3C for the following:
― Short to ground
― Short to power supply
― Open circuit
• Is there continuity?
Yes
Go to next step.
No
Repair the wiring harness between the keyless receiver and keyless control module.
Go to next step.
3
INSPECT KEYLESS RECEIVER POWER SUPPLY CIRCUIT
• Turn the ignition switch to the ON position.
• Measure voltage at terminal 3A of keyless control module connector.
• Is voltage more than 7.5 V?
Yes
Replace keyless receiver.
No
Replace the keyless control module and perform the resetting procedure for the advanced keyless system when replacing the keyless control module.