id0902e8999600
| DESCRIPTION |
• Configuration error
• Configuration has not been performed
|
|---|---|
|
DETECTION CONDITION
|
• Instrument cluster detects the erratic configuration data when the ignition switch is ON.
|
|
POSSIBLE CAUSE
|
• Instrument cluster configuration not implemented
• Instrument cluster malfunction
|
Diagnostic Procedure
| STEP |
INSPECTION |
ACTION |
|
|---|---|---|---|
|
1
|
PERFORM INSTRUMENT CLUSTER CONFIGURATION
• Perform the “INSTRUMENT CLUSTER CONFIGURATION” using the M-MDS. (See
INSTRUMENT CLUSTER CONFIGURATION.)
• Clear the DTC from the instrument cluster using the M-MDS. (See
CLEARING DTC [INSTRUMENT CLUSTER].)
• Turn the ignition switch to the ON position.
• Perform the “DTC INSPECTION” using the M-MDS. (See
DTC INSPECTION [INSTRUMENT CLUSTER].)
• Is the same DTC present?
|
Yes
|
Perform the “INSTRUMENT CLUSTER CONFIGURATION” again, then go to the next step.
|
|
No
|
Go to Step 3.
|
||
|
2
|
VERIFY TROUBLESHOOTING COMPLETED
• Clear the DTC from the instrument cluster using the M-MDS. (See
CLEARING DTC [INSTRUMENT CLUSTER].)
• Turn the ignition switch to the ON position.
• Perform the “DTC INSPECTION” using the M-MDS. (See
DTC INSPECTION [INSTRUMENT CLUSTER].)
• Is the same DTC present?
|
Yes
|
Replace the instrument cluster, then go to the next step.
|
|
No
|
Go to the next step.
|
||
|
3
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
|
No
|
DTC troubleshooting completed.
|
||