No.5 DOOR GLASS STOPS BEFORE FULLY OPENING/CLOSING [EXTERIOR OPEN/CLOSE FUNCTION]SM2446056
No.5 DOOR GLASS STOPS BEFORE FULLY OPENING/CLOSING [EXTERIOR OPEN/CLOSE FUNCTION]

id090397809000

5
DOOR GLASS STOPS BEFORE FULLY OPENING/CLOSING
POSSIBLE CAUSE
• Power window main switch malfunction
• Power window subswitch malfunction
• Power window motor malfunction
• Battery malfunction (Low voltage)
• Door glass improper installation
• Power window initialization procedure error
• Keyless control module malfunction
• BCM malfunction
• Keyless entry system signal reception error (outside operation area, radio signal interference)

Diagnostic Procedure

Step

Inspection

Action

1
• Operate the door glass in auto/manual by operating the power window main switch/power window subswitch.
• Does the door glass stop before fully opening/closing using either operation?
Yes
Inspect the following parts, and repair or replace.
• Power window main switch (See POWER WINDOW MAIN SWITCH INSPECTION.)
• Power window subswitch (See POWER WINDOW SUBSWITCH INSPECTION.)
• Power window motor (See POWER WINDOW MOTOR INSPECTION.)
• Battery (Low voltage)
• Door glass (Installation condition)
No
Go to the next step.
2
• Inspect the operation of the door glass by repeating Step 1 above.
• Does the door glass stop before fully opening/closing while in auto operation?
Yes
Perform the power window initialization procedure.
No
Go to the next step.
3
• Open the door glass by operating the transmitter.
• Does the door glass stop before fully opening?
Yes
Inspect the following parts, and repair or replace.
• Keyless control module (Vehicles with advanced keyless system) (See KEYLESS CONTROL MODULE INSPECTION [ADVANCED KEYLESS ENTRY AND START SYSTEM].)
No
Go to the next step.
4
• Close the door glass by operating the transmitter.
• Does the door glass stop before fully closing?
Yes
Inspect the following parts, and repair or replace.
• Keyless control module (Vehicle with advanced keyless system) (See KEYLESS CONTROL MODULE INSPECTION [ADVANCED KEYLESS ENTRY AND START SYSTEM].)
• Keyless entry system signal reception error (outside operation area, radio signal interference)
No
Reinspect for malfunction recurrence.If the malfunction is not corrected, repeat the procedure from Step 1.