id0903d5807900
| 6 |
Instrument cluster illumination does not illuminate |
|---|---|
|
POSSIBLE CAUSE
|
• Instrument cluster malfunction
• Connector or pin malfunction
• Fuse malfunction
|
Diagnostic procedure
| STEP |
INSPECTION |
ACTION |
|
|---|---|---|---|
|
1
|
• Turn the light switch to the TNS position.
• Does the instrument cluster illumination turn on?
|
Yes
|
Troubleshooting completed.
|
|
No
|
Go to the next step.
|
||
|
2
|
• Turn the light switch to the TNS position.
• Does the TNS turn on?
|
Yes
|
Go to the next step.
|
|
No
|
Inspect and repair the following TNS related parts and wiring harness.
|
||
|
3
|
• Turn the ignition switch to the LOCK position.
• Remove the instrument cluster.
• Disconnect the instrument cluster connector.
• Turn the light switch to the TNS position.
• Inspect the voltage instrument cluster wiring harness-side connector terminal 2I.
• Turn the ignition switch to the ON position.
• Is the voltage B+?
|
Yes
|
Repair wiring harness for open between TNS relay and instrument cluster terminal 2I.
|
|
No
|
Go to the next step.
|
||
|
4
|
• Turn the ignition switch to the LOCK position.
• Inspect the instrument cluster connector terminals for poor connection (such as damaged/pulled-out pins, and corrosion).
• Are the terminals normal?
|
Yes
|
Replace the instrument cluster.
|
|
No
|
Repair or replace the terminal.
|
||