id091200002300
Auto-Open/Close
1.Measure the voltage at each terminal (other than terminals H and I).
2.Disconnect the negative battery cable.
3.Inspect the power window subswitch connector for continuity at terminals H and I.
4.If the system does not work properly even though the inspection items or related wiring harnesses do not have any malfunction, replace the power window subswitch.
acxuuw00001387
|
| Terminal |
Signal name |
Connected to |
Measured condition |
Voltage (V)/Continuity |
Inspection item (s) |
|---|---|---|---|---|---|
|
A
|
Communication
|
Power window main switch
|
Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
|
—
|
|
|
B
|
Power supply
|
Power window motor
|
Ignition switch at ON or during IG-OFF timer
|
B+
|
• Power window motor (See
POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
|
C
|
Close output
|
Power window motor
|
While door glass is opening
|
1.0 or less
|
• Power window motor (See
POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
|
While door glass is closing
|
B+
|
||||
|
D
|
Sensor ground
|
Power window motor
|
Under any condition:
|
1.0 or less
|
• Power window motor (See
POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
|
F
|
GND
|
Body ground
|
Under any condition:
|
1.0 or less
|
• GND
|
|
H
|
Pulse 2
|
Power window motor
|
Door glass moving
|
Alternates between 1.0 or less and B+
|
• Power window motor (See
POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
|
Door glass stopped
|
1.0 or less or B+
|
||||
|
I
|
Power supply
|
P.WIND 2 30 A fuse
|
Under any condition
|
B+
|
• P.WIND 2 30 A fuse
• Related wiring harnesses
|
|
J
|
Pulse 1
|
Power window motor
|
Door glass moving
|
Alternates between 1.0 and B+
|
• Power window motor (See
POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
|
Door glass stopped
|
1.0 or less or B+
|
||||
|
K
|
Open output
|
Power window motor
|
While door glass is opening
|
B+
|
• Power window motor (See
POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
|
While door glass is closing
|
1.0 or less
|
||||
|
L
|
Power-cut signal
|
Power window main switch
|
Ignition switch at ON and power-cut switch at UNLOCK
|
B+
|
• Power window main switch (See
POWER WINDOW MAIN SWITCH INSPECTION)
• Related wiring harnesses
|
Manual Open/Close
1.Inspect for continuity between the power window subswitch terminals.
acxuuw00001388
|
acxuuw00001389
|