id0914008076z6
1.Measure the voltage or inspect for continuity according to the Terminal Voltage Table (Reference).
2.If the system does not work properly even though the inspection items or related wiring harnesses do not have any malfunction, perform symptom troubleshooting.
Terminal Voltage Table (Reference)
acxwzw00001699
|
| Terminal |
Signal name |
Connected to |
Measured condition |
Voltage (V)/Continuity |
Inspection item(s) |
|---|---|---|---|---|---|
|
A
|
Power supply
|
Keyless control module
|
Under any condition
|
B+
|
Keyless control module
|
|
B
|
Power supply
|
ROOM 15 A fuse
|
Under any condition
|
B+
|
ROOM 15 A fuse
|
|
C
|
DATA
|
Keyless control module
|
Terminal used for communication therefore determination based on terminal voltage inspection not possible.
|
Keyless control module
|
|
|
E
|
GND
|
Body ground
|
Under any condition: Inspect for continuity to ground.
|
1.0 or less
|
GND
|