SECURITY ACCESS PROCEDURESM2446313
SECURITY ACCESS PROCEDURE
id091400810300
1.Connect the M-MDS to the DLC-2.
2.After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
-
• When using the IDS (laptop PC)
-
1. Select “Body”
2. Select “Security”
3. Select “PART Functions”
-
• When using the PDS (Pocket PC)
-
1. Select “All Tests and Calibrations“.
2. Select “PART Functions“.
3.Then, select items from the screen menu in the following order.
-
1. Select “PATS Functions”
4.Select the items to be performed from the following:
-
• Program Additional Advanced Key
• Advanced Key Code Erase and Program
• Steering Lock Unit Programming
• Program Additional Ignition Key
• Ignition Key Code Erase and Program
• Customer Spare Key Programming Enable
• Customer Spare Key Programming Disable
• Parameter Reset
5.The security access begins and the M-MDS displays the “OUT-CODE”.
-
Note
-
• When “OUT-CODE” is first displayed, turning the ignition switch from the LOCK to the ON position
5 times will change the “OUT-CODE”.
6.Input “IN-CODE” corresponding to “OUT-CODE” displayed on the M-MDS screen.
7.If the security access is successful, selected item can be performed.