UREA TANK TEMPERATURE SENSOR INSPECTION [MZR-CD 2.2]

id0140f2424900


Resistance Inspection

1.Disconnect the negative battery cable.

2.Disconnect the urea tank temperature sensor short cord connector (connector with 7 wiring harnesses connected).

3.Verify that the resistances between the following terminals are within the specification using an ohmmeter.

• Urea level sensor short cord connector E—J
― If not within the specification, replace the malfunctioning part. (See UREA TANK REMOVAL/INSTALLATION [MZR-CD 2.2].)
Specification
8.8—11.2 kΩ