NEUTRAL SWITCH INSPECTION [L3 Turbo]


id0140b6800800

Note
•  Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart. (See HOW TO USE THIS MANUAL.)

Continuity Inspection

1.  Remove the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [A26MX-R].)

2.  Verify that the continuity between neutral switch terminals A and B is as indicated in the table.

acxaaw00000931

•  If it can be verified, perform the “Circuit Open/Short Inspection”.
•  If it cannot be verified, replace the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [A26MX-R].)

Measured condition

Continuity

Rod pushed
Continuity detected
Except above
No continuity


Circuit Open/Short Inspection

acxaaw00000932
acxaaw00000933

1.  Disconnect the PCM connector.

2.  Inspect the following wiring harness for an open or short circuit. (Continuity inspection)


Open circuit

•  If there is no continuity in the following wiring harnesses, there is an open circuit. Repair or replace the wiring harness.
―  Neutral switch terminal A and body ground
―  Neutral switch terminal B and PCM terminal 1S


Short circuit

•  If there is continuity in the following wiring harnesses, there is a short circuit. Repair or replace the wiring harness.
―  Neutral switch terminal A and ground