NO.5 NO TEMPERATURE CONTROL WITH CLIMATE CONTROL UNIT
id070300800800
5
|
No temperature control with climate control unit
|
DESCRIPTION
|
• Malfunction in A/C unit and/or climate control unit air intake system
|
POSSIBLE CAUSE
|
• A/C unit air intake link, air intake crank, air intake rod, air intake wire, wire clamp malfunction
• Climate control unit rack-and-pinion, air intake wire malfunction
• A/C unit air intake door malfunction
• Heater piping malfunction
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT COOLANT TEMPERATURE
• Is the coolant sufficiently warmed up?
|
Yes
|
Go to the next step.
|
No
|
Warm up the engine, then go to Step 8.
|
||
2
|
INSPECT A/C UNIT AIR INTAKE SYSTEM
• Inspect the A/C unit air intake links, air intake cranks, air intake rods, air intake actuator, and wire clamp.
• Are the above items normal?
|
Yes
|
Go to the next step.
|
No
|
Apply grease or install the links, cranks, and rods securely in their proper positions, repair or replace the air intake actuator or wire clamp, then go to Step 8.
|
||
3
|
VERIFY THAT AIR INTAKE WIRE FROM A/C UNIT IS POSITIONED SECURELY AND CORRECTLY (IF AVAILABLE)
• Is the air intake wire securely installed in the correct position in relation to the A/C unit air mix links?
|
Yes
|
Go to the next step.
|
No
|
Adjust the air intake wire or install securely in the correct position, then go to Step 8.
|
||
4
|
INSPECT CLIMATE CONTROL UNIT
• Inspect the climate control unit.
• Is the climate control unit normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the climate control unit, then go to Step 8.
|
||
5
|
INSPECT A/C UNIT
• Is there any foreign material or obstruction in the A/C unit air intake doors?
|
Yes
|
Remove obstruction, then go to Step 8.
|
No
|
Go to the next step.
|
||
6
|
INSPECT A/C UNIT AIR INTAKE DOOR
• Is the A/C unit air intake door securely and properly installed?
|
Yes
|
Inspect the air intake door for cracks or damage, then go to the next step.
|
No
|
Install the air intake door securely in the proper position, then go to the next step.
|
||
7
|
INSPECT HEATER LINE
• Inspect the heater lines.
• Are the above items normal?
|
Yes
|
Operation is normal. Recheck malfunction symptoms.
|
No
|
If heater piping connections are loose, tighten the connections to the specified torque.
Repair or replace the heater piping, then go to the next step.
|
||
8
|
VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR
• Does the unit operate in every temperature setting?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.
|