SLIDE MOTOR INSPECTION


id091300800900

1.  Disconnect the slide motor connector.

2.  Apply battery positive voltage to the slide motor terminals and inspect the slide motor operation.

acxaaw00000043

•  If not as specified, replace the slide adjuster.

Motor operation

Connection

B+

GND

Forward
A
B
Backward
B
A