REAR AUTO LEVELING SENSOR INSPECTION


id091800806800

1.  Connect three 1.5 V dry cell batteries in a series.

acxaaw00001022

2.  Connect the positive pole of the battery to rear auto leveling sensor terminal C, and the negative pole to terminal A, then apply voltage of 4.5 V between terminals C and A.

3.  Connect the tester as shown in the figure.

4.  Measure the voltage while the link is moved up and down slowly.

acxaaw00001276

•  If not as indicated in the table, replace the rear auto leveling sensor.